Submitted by:
chewblocka (Matthew Block)
Description:
This is a template for additional data collection on PowerEdge 2950 servers. It would also probably prove useful on other Dell devices that use OpenManage, but may need a little tweaking (as far as number of processors, etc). It currently does the following:
Collect data points for
- Temperature Probe Reading (1/10 Degree Celcius)
- Fan RPM (4 fans)
- Processor Status (2 CPUs)
- Memory Device Status (8 Memory slots)
- Power Supply Status (2 PSUs)
- Array Disk State (6 disks)
Thresholds are setup for
- Critical event for Disk Array status other than 3 (ok)
- Warning event for Fan RPM < 3450
- Critical event for Memory Status other than 3 (ok)
- Critical event for Power Supply Status other than 3 (ok)
- Critical event for Processor Status other than 3 (ok)
- Warning event for Temperature > 42 or < 8 degrees c
Graphs for
- Temperature reading
- Fan RPM
Screenshots:
REQUIREMENTS:
Zenoss Version: 2.2
ZenPack Dependencies:
External Dependencies:
Installation:
Source: http://zenpacks.zenoss.org/trac-zenpacks/browser/zenpacks/
Tagged Releases:
http://zenpacks.zenoss.org/trac-zenpacks/browser/tags/
Change History:
Trac tickets: http://zenpacks.zenoss.org/trac-zenpacks/report/1
Known issues: