Apr 16, 2010 11:36 AM
Template bindings reset every 24 hours
-
Like (0)
I have templates bound and set at the Class level in addition to the device level. For example, I have the class 'database' and the bound performance templates are Device and MySQL.
My problem is I will go to the device, and click Reset Bindings and it gets the Device template, but 24 hours later only the MySQL template is bound. This happens to all my devices, not just in the database class. If I manually bind the Device template to the device, 24 hours later it is removed.
I've checked the log files and don't see anything related to templates being removed. I have trimmed down the various collector plugins, and mostly use community.snmp.HP* since they are HP blades.
Any ideas or suggestions?
It was the HP SYSTEMS INSIGHT MANAGER AGENTS MONITOR zenpack that caused my issue. I have linux servers and this zenpack is for windows. When I removed the hpsimmonitor collector plugin, the Device template would stay bound to the device.
I found this by turning debugging on for all daemons and remodeling the device. There was an entry from this zenpack about current templates, and after the remodeling was finished, the Device template was removed.