    I'd do the following (shotgun approached based on not know what has been done, and current state):

    1) Clear anyevents for the device in question

    2) Delete the bigip devices you added previously via the 'non-direct' approach

    3) Restart Zenoss

    4) Re-added the bigips using the UI, ensuring you select /network/f5 from the device add screen (not after the fact), be sure to put the proper snmp string and all that jazz on that single screen (You shouldnt need to touch device after adding)

    5) See if any of the events come back

    6) See if zenperfnsmp reflects any run details (not success:0 fail:0 pending:0 todo:0)

     

    Again I don't have any data to suggest that all of the above will fix anything, but it would allow further troubleshooting to be done from a clean slate.

  • dpetzel Rank: Brown Belt 1,141 posts since
    Oct 17, 2010
    Currently Being Moderated
    17. Nov 8, 2011 6:55 AM (in response to Robert Bell)
    Re: device report errors

    Regular Expression, I also updated docs/DOC-11352 to clarify that it accepts a regular expression.